• XEAL@lemm.ee
    link
    fedilink
    arrow-up
    95
    ·
    7 months ago

    I love how the warning just asks you to make sure but doesn’t really try to talk you out of it.

      • idunnololz@lemmy.world
        link
        fedilink
        arrow-up
        14
        ·
        edit-2
        7 months ago

        This business kind of sucks. If you make good quality products it will work too well so no one would ever recommend it so you get no exposure. If you make shitty quality ones all the ones that survive is going to bitch about it and lawsuits and blah blah blah.

        Anyways if anyone has any ideas on how to turn this business around let me know.

        • pivot_root@lemmy.world
          link
          fedilink
          arrow-up
          6
          arrow-down
          1
          ·
          edit-2
          7 months ago

          The funny part is that it wouldn’t even work.

          If the plug was on a GFCI outlet, it would trip once neutral and hot are shorted.

          If it wasn’t on a GFCI outlet, it would be an inefficient water heater. Current is inversely proportional to resistance, and the inch of tap water between both conductors has a significantly lower resistance than the human sitting at the other side of the tub. At American voltages of 110V, the worst thing that will probably happen is the wires heat up from the current passing through them. Now, if it only had the live wire exposed and you had a metal tub, that might be a different story…

          • Rivalarrival@lemmy.today
            link
            fedilink
            English
            arrow-up
            9
            ·
            7 months ago

            You assume the neutral wire is present and connected to the neutral prong, as it is in typical appliances. If I were to make this ducky, I wouldn’t connect anything to the neutral or ground prongs in the plug. Indeed, I’d connect all three wires in the cord to the hot prong.

            • pivot_root@lemmy.world
              link
              fedilink
              arrow-up
              3
              ·
              edit-2
              7 months ago

              That is my first assumption, yeah. I did note at the end if they intentionally didn’t connect neutral and ground and it was a metal tub, that would work

          • nilloc@discuss.tchncs.de
            link
            fedilink
            English
            arrow-up
            5
            ·
            7 months ago

            It’s got a British plug so it’s at least 200 volts.

            But yeah, probably ok if the water isn’t too salty and you stay away from touching the electrodes.

            I’m still not getting in with one though. At over 6 feet, I take up the whole tub + most of the time anyway.

            • Rivalarrival@lemmy.today
              link
              fedilink
              English
              arrow-up
              1
              ·
              7 months ago

              But yeah, probably ok if the water isn’t too salty

              If you’re going to be passing a current through your bath water, you would want the bath water to be as conductive as possible. You don’t want the salt water in your body to be the path of least resistance. You want the current to flow around you, not through you.