help-circle



  • Its not poor quality control, its chemistry.

    There is a potential of 2 electron volt between copper and aluminium. If both materials are electrically connected, electromigration starts to eat away the aluminium. The radiator will leak soon.

    That is why you cannot put normal water in the loop. Manufacturers use non conductive liquid and special inhibitors so that almost no electromigration takes place. As soon as you open it, the liquid can get contaminated which will make it conductive again. Inhibitors also don’t last forever, so every all in one has a built in self destruct.

    The only solution is to switch to a copper radiator. the block and pump are usually fine. But the microfin array is where the corroded aluminium will build up. You likely replaced the wrong part.